. This Manual Must Always be Available to the Stove Operator Installation & Servicing Instructions Nestor Martin IQ13 Smoke Control IN1264 Edition A October 2012 Exempt PART NUMBER SERIAL NUMBER This manual must be used in conjunction with document IN1173. The Wood and Mutlifuel Chimney. Table of Contents The Model Range Explained. 3 Technical Data, Intermittent Operation.5 Technical Data, Continuous Operation.5 General Technical Data. 5 IQ13 Aperture Size.5 IQ13 Dimensions.
6 Housing Construction, without an Existing Chimney Breast.8 Ideal installation. The Model Range Explained Thank you for purchasing your stove and helping to protect our environment.
Nestor Martin and Euroheat insist on progressive development to produce products which are market leading. Our aims are to produce stoves with the latest innovations, user friendly operation and highly efficient for lower cost operation. When burning wood you will be greatly assisting with reducing CO².
IMPORTANT The installation of this appliance must comply with all local regulations, including those referring to national and European Standards before it can be operated. The stove is not suitable for a shared flue. However, for England and Wales, only, the coming into force on 1st April 2002 of SI 2002 No 440 exempts the householder from this legal requirement for the installation of solid fuel fired appliance whose rated heat output is 50kW or less in a building having no more than 3 storeys (excluding any basement) if a Competent Engineer is employed who is registered under the Registration Scheme for Companies and Engineers involved in the Installation and Maintenance of.
![]()
Interval Efficiency Model Wood Wood Wood Smokeless Smokeless Smokeless Coal. Coal. Coal. 77.1% Net IQ13 Wood 5 kW 0.70 hr 70.2% Gross 77.1% Net 82.8% Net IQ13 Multifuel 5 kW 0.70 hr 3.5 kW 1.05 hr 70.2% Gross 75.4% Gross.
IQ13 Dimensions Dimensions mm Height 3 sided 50mm frame/25mm frame 605/580 Height 4 sided 50mm frame/25mm frame 626/576 Width of body Depth of body Height of body Height including flue spigot Front to heat vent outlet centre Front to flue outlet centre Flue diameter (internal diameter) Optional heat vent diameter (internal diameter) Centre between flue and heat vent. Supplied with the Stove Flue Spigot and Self-adhesive Rope Plexus Cover Plate Only used if fresh air kit is to be fitted Stove Operating and Ash Pan Tool 1 x Heat Resistant Leather Glove Fresh Air Spigot Only used if fresh air kit is Large Allen Key to be fitted Small Allen Key. Housing Construction, when Using an Existing Chimney Breast Whilst it is almost certain that the fabric of an existing fireplace and chimney will be non-combustible and will have a hearth which conforming to the regulations, should be inspected to ensure that it has not been modified by an over zealous “do it yourselfer”. The stove’s flue spigot is fitted to the flue pipe by pushing it upwards from within the stove so that the flue can be positioned exactly, before in filling the fireplace to give the required housing size. A register plate should now be fitted. If a secondary lintel is to be fitted with only a single thickness of brick to be used as the closure, the inner face of the bricks should be faced with insulation material to reduce the temperature of the wall face. Rockwool, fibreglass or several layers of Glasrock are suitable.
Housing Construction, without an Existing Chimney Breast If the property has no existing chimney or chimney breast the first consideration will be the positioning of the flue. Taking the flue to the roof internally through the property will involve complying with many regulations and even an external flue may be subject to planning regulations. The insulating properties of many modern houses are extremely high and many external walls are now constructed with an inner skin of plasterboard, supported on a wooden frame which is thermally insulated from the outer skin of brick.
Having such a low thermal conductivity makes it impossible to use the outer wall as the back of the stove’s housing unless a means of ensuring that non of the heat from the stove is transferred to the house wall. Ideal Installation Cowl to prevent ingress of rain, birds and to assist Flue liner reaching to with flue stabilization top of the termination and insulated Flue liner support collar Weatherproof chimney which is required for both pot and parged at a flexible and single wall steep angle to disperse liners. Installation of Flue Spigot to Flue Pipe The flue spigot is mounted internally within the top of the stove retained by four bolts, see picture below.
The top chamber baffle may be in place and will need to be removed to gain access to fit the flue spigot. This baffle is held in place by two bolts and the baffle MUST be replaced once the flue has been connected.
The Hearth and Fire Surround Whilst the existing regulations require the hearth to protrude in front of a solid fuel appliance by a minimum of 250mm we strongly recommend that this distance should be 300mm. These rules make provision for the protection of the property in the event of burning fuel falling from the fire, but the height of the fire bed in an open fire or conventional stove is not very high and as the horizontal distance any falling item travels is, amongst other factors, dependant upon the height from which it starts, it should be apparent that anything falling from an. Minimum Air Setting The minimum air screw should be adjusted to supply the maximum air setting, by screwing it in a anti-clockwise direction until the shutter is fully open when resistance to further turning will be felt, before the stove is lit for the first time.
Firebox Components Removal of the Top Mica Baffle Plate The top mica baffle is located in the top of the fire box where it sits on the L shaped baffle support lugs which are part of the casting of the left and right side protection plates. For easier access remove the front fuel guard. Removal of the Rear Protection Plate To remove (1) lift up the plate so it is higher than the lugs on the grate frame and then (2) draw it towards the centre of the fire box. As it is drawn towards the centre twist the edge towards the front of the fire box. Euroheat Technical Team Information from the Euroheat Technical Team Euroheat and Nestor Martin have a policy of continual research and development and reserve the right to modify its appliances without prior notice. We make every effort to ensure that the information provided in this document is correct and accurate at the time of printing.
Need more info? With over 10,000 pages of technical information, spare parts, product shots, news and 1001 other things, - you will not find a more comprehensive solution to your queries, whatever time of the day. Www.euroheat.co.uk Court Farm Business Park, Bishops Frome, Worcestershire WR6 5AY Pre sales: 12.
Weber smokey mountain smoker directions. The Southco Lift and Turn Latch provides for smooth, accurate closure with the added confidence of a positive seal to your Weber Smoker Mountain door. A viable upgrade to the standard Weber knob/latch. Can be used on the Cajun Bandit or any other single walled smoker such as WSM.
![]() Nestor Martin Stoves
. Installation Instructions For HARMONY H13, H23, H33, H43 STANFORD S13, S23, S33, S43 SP23, SP33, SP43 NESTOR MARTIN R23, R33 RH33, FH33 Wood and Multifuel Stoves With Plexus Control and ZR Technology This manual must be used in conjunction with document IN1173. IMPORTANT The installation of this appliance must comply with all local regulations, including those referring to national and European Standards before it can be operated.
The stove is not suitable for a shared flue. However, for England and Wales, only, the coming into force on 1st April 2002 of SI 2002 No 440 exempts the householder from this legal requirement for the installation of solid fuel fired appliance whose rated heat output is 50kW or less in a building having no more than 3 storeys (excluding any basement) if a Competent Engineer is employed who is registered under the Registration Scheme for Companies and Engineers involved in the Installation and Maintenance of. Our aims are to produce stoves with the latest innovations, user friendly operation and highly efficient for lower cost operation. This manual offers installation information for the range of HARMONY H13, H23, H33, H43. STANFORD S13, S23, S33, S43 SP23, SP33, SP43. NESTOR MARTIN R23, R33 RH33, FH33.
12pa Stanford 43 S43. 10.5Kw 11.3kW 12pa See smoke control Stanford SP43 HP SP43 HP. 10.5Kw 11.3kW 12pa exempted Nestor Martin R23 R23. 5.9kW 6.1kW 12pa table Nestor Martin R33 7.9kW 8.4kW 12pa Nestor Martin RH33 RH33. 8.4kW 7.2kW 12pa. 72.8.
Stanford 43 7” (180mm) 4125mm 2 80. 72.8. Stanford SP43 HP 7” (180mm) 1100mm 2 73. 65.7. Nestor Martin R23 6” (153mm) Approved 2750mm 2 77.6 Nestor Martin R33 6” (153mm) Approved 2750mm 2 77.6. 69.7.
Nestor Martin RH33 7”. Useful Organisations UK Solid Fuel Association 0845 601 4406 www.solidfuel.co.uk The National Association of Chimney Sweeps 32 www.chimneyworks.co.uk HETAS Ltd. 0845 634 5626 www.hetas.co.uk Stoves Construction The plexus control is the centre of the air inlet system. The fuel select lever, controls the direction of air flow, either air wash or under grate. Stanford 33 A or B Stanford SP33 Stanford 43 Yes (only enamel models) Stanford SP43 Nestor Martin R23 Nestor martin R33 A or B Nestor Martin RH33 Nestor Martin FH33 © EUROHEAT DISTRIBUTORS (H.B.S) LTD.
June 2008 E & OE. The Nestor Martin R23, R33, RH33, FH33 have an additional top closing plate for the top cover.
This is retained in place by a square steel plate which is supplied with the stove. This plate slides into fixings under the top removable plate. Fireplace Design Do not be tempted to fit the stove into an unsuitable fireplace. Beyond the requirements of Building Regulations and access to facilitate servicing the stove, providing a setting which will compliment a stove is not a luxury, it is the practicality of making the most of an investment. A good builder or fireplace specialist will be able to transform even the most utilitarian of fireplaces. Stanford 43 Wood 300mm 250mm 300mm 300mm 250mm 12mm Stanford SP43 Wood 300mm 250mm 300mm 300mm 250mm 12mm Nestor Martin R23 Wood 300mm 250mm 300mm 300mm 250mm 12mm Nestor Martin R33 Wood 300mm 250mm 300mm 300mm 250mm 12mm Nestor Martin RH33 Wood.
Minimum Installation Clearances From Non-combustible Materials. From Non-combustable materials 100mm 75mm 300mm 50mm 75mm 12mm. If a remote control is to be used with the appliance, the distance E requires to be increased to at least 100mm to allow access to the remote control receiver. If this space is not available a remote mounted receiver can be installed. The Flue It is possible to remove the top chamber baffle to access the flue for cleaning. However we would advise that if at all possible an external cleaning access is provided.
Nestor Martin Vintage Parlor Wood
If the chimney has been lined with the same size flue as the flue pipe it will be possible to sweep from the flue access point. Remote Control Option This stove has the option of remote control.
Fitting the Remote Control Motor At the rear of the appliance you will see the motor fitting bracket. This incorporates a magnet and the mechanism friction plate. The friction plate is hinged. To fit the motor this friction plate needs to be detached from the magnet and swung to the left. Complete the Stoves Registration Form and Pass to User for Registration Euroheat, Efel and Nestor Martin have a policy of continual research and development and reserve the right to modify its appliances without prior notice. We make every effort to ensure that the information provided in this document is correct and accurate at the time of printing.